タイトル: TIA を用いたVCSEL の自己結合型近距離計に関する研究
その他のタイトル: TIA ヲ モチイタ VCSEL ノ ジコ ケツゴウ ガタ キンキョリ ケイ ニ カンスル ケンキュウ
Study on short distance meter based on self-coupling effect of VCSEL using TIA
著者: 神野, 美子
津田, 紀生
山田, 諄
JINNO, Yoshiko
TSUDA, Norio
YAMADA, Jun
発行日: 2009年3月31日
出版者: 愛知工業大学
抄録: Recently, making use of self-coupling effect of VCSEL, a compact distance meter has been studied. In this distance meter, self-coupling signal has been processed by FFT to obtain a distance information. However the real time measurement is difficult as FFT analyze takes time. Then a short distance meter based on self-coupling effect of VCSEL using Time Interval Analyzer (TIA) is studied. By TIA, the time interval of each self-coupling pulse is measured and the frequency distribution is obtained. Thereby, a distance is calculated by statistically processing the frequency distribution. It is found that the measurement error by TIA is 1/10 less than that by averaging the total self-coupling pulse, that is by using a counter.