AIT Associated Repository of Academic Resources >
A.研究報告 >
A1 愛知工業大学研究報告 >
4.愛知工業大学研究報告 (2008-) >
44号 >
このアイテムの引用には次の識別子を使用してください:
http://hdl.handle.net/11133/1436
|
タイトル: | TIA を用いたVCSEL の自己結合型近距離計に関する研究 |
その他のタイトル: | TIA ヲ モチイタ VCSEL ノ ジコ ケツゴウ ガタ キンキョリ ケイ ニ カンスル ケンキュウ Study on short distance meter based on self-coupling effect of VCSEL using TIA |
著者: | 神野, 美子 津田, 紀生 山田, 諄 JINNO, Yoshiko TSUDA, Norio YAMADA, Jun |
発行日: | 2009年3月31日 |
出版者: | 愛知工業大学 |
抄録: | Recently, making use of self-coupling effect of VCSEL, a compact distance meter has been studied. In this distance meter, self-coupling signal has been processed by FFT to obtain a distance information. However the real time measurement is difficult as FFT analyze takes time. Then a short distance meter based on self-coupling effect of VCSEL using Time Interval Analyzer (TIA) is studied. By TIA, the time interval of each self-coupling pulse is measured and the frequency distribution is obtained. Thereby, a distance is calculated by statistically processing the frequency distribution. It is found that the measurement error by TIA is 1/10 less than that by averaging the total self-coupling pulse, that is by using a counter. |
URI: | http://hdl.handle.net/11133/1436 |
出現コレクション: | 44号
|
このリポジトリに保管されているアイテムは、他に指定されている場合を除き、著作権により保護されています。
|