  <entry>
    <title>電力系統過渡安定度に関するアナログシミュレーション</title>
    <link rel="alternate" href="http://hdl.handle.net/11133/212" />
    <author>
      <name>小林, 英夫</name>
    </author>
    <author>
      <name>一柳, 勝宏</name>
    </author>
    <id>http://hdl.handle.net/11133/212</id>
    <updated>2013-01-10T16:31:18Z</updated>
    <published>1968-11-30T15:00:00Z</published>
    <summary type="text">タイトル: 電力系統過渡安定度に関するアナログシミュレーション
著者: 小林, 英夫; 一柳, 勝宏
抄録: Adoptions of forced excitation, switched series condenser and damping resistor are, as well known, very effective to improve the transient stability of power systems. Some experiments, in respect of the compensative effects of forced excitation and switched series condenser against the step out caused by faults, were executed and its consequences are showed. Analogue computer simulation results on transient stability regions, in case that we take the switching times of excitation voltage and line constant as parameters, are described.</summary>
    <dc:date>1968-11-30T15:00:00Z</dc:date>
  </entry>
  <entry>
    <title>懸垂吸音体の吸音特性について(第1報) : 板状繊維質材料について</title>
    <link rel="alternate" href="http://hdl.handle.net/11133/213" />
    <author>
      <name>成瀬, 治興</name>
    </author>
    <id>http://hdl.handle.net/11133/213</id>
    <updated>2013-01-10T16:31:20Z</updated>
    <published>1968-11-30T15:00:00Z</published>
    <summary type="text">タイトル: 懸垂吸音体の吸音特性について(第1報) : 板状繊維質材料について
著者: 成瀬, 治興
抄録: We know that suspended absorbers are available for acoustic improvement of interior, but few fundamental studies have hitherto been made on it. This experimental study is made fundamentally on the acoustical characteristics of suspended absorbers, using fibered plates.</summary>
    <dc:date>1968-11-30T15:00:00Z</dc:date>
  </entry>
  <entry>
    <title>水道本管の経済的直径と平均流速公式</title>
    <link rel="alternate" href="http://hdl.handle.net/11133/214" />
    <author>
      <name>富永, 保夫</name>
    </author>
    <id>http://hdl.handle.net/11133/214</id>
    <updated>2013-01-10T16:31:20Z</updated>
    <published>1968-11-30T15:00:00Z</published>
    <summary type="text">タイトル: 水道本管の経済的直径と平均流速公式
著者: 富永, 保夫
抄録: We adopt Williams &amp; Hazen Formula as mean velocity formula. Nowadays this is used most widely in the Public Water Supplies of the United States and Japan. We show for economical pipe diameter the numeral value that has been calculated by as new data as possible. The formula which Mr. Hikoichi Ogida has made is thought best as theoretical formula, we used it. Therefore, the following three formulas are made. d(m) =Q^&lt;0.4342&gt;………………………………………(11) Q(m^3/s) =d^&lt;2.308&gt;……………………………………(12) i(‰)=2.1101・d^&lt;-0.605&gt;………………………………(13)</summary>
    <dc:date>1968-11-30T15:00:00Z</dc:date>
  </entry>
  <entry>
    <title>タングステン ポイントフィラメントの電界放出模様の観察(III) : バイアス電圧の影響について</title>
    <link rel="alternate" href="http://hdl.handle.net/11133/207" />
    <author>
      <name>竹松, 英夫</name>
    </author>
    <author>
      <name>北村, 隆</name>
    </author>
    <author>
      <name>森田, 千明</name>
    </author>
    <id>http://hdl.handle.net/11133/207</id>
    <updated>2013-01-10T16:31:18Z</updated>
    <published>1968-11-30T15:00:00Z</published>
    <summary type="text">タイトル: タングステン ポイントフィラメントの電界放出模様の観察(III) : バイアス電圧の影響について
著者: 竹松, 英夫; 北村, 隆; 森田, 千明
抄録: In order to study the electron optical properties of a point filament in the electron microscope gun, this experiment has been worked. Successive observations of the field emision patterns of a point filament were made by variation of the bias voltage. As a result it was found that the brightness and size of the pattern depended on the bias voltage, and the field emission pattern and the thermoionic pattern were superposed in the case of using the filament at higher temperature. It may be said that the pre-treatment of the filament has an effect on the field emission pattern at lower temperature.</summary>
    <dc:date>1968-11-30T15:00:00Z</dc:date>
  </entry>
</feed>
